Electro Neurostere produces electrical impulses that relieves pain. It also accelerates the reunion of fracture. The electrical impulses work to stimulate bone growth, in that it appears to trigger certain chemical process that normally take place during bone development. This instrument is tested at many centres in India and found to be eminently useful in relieving pain. RELIEVES a) Acute Sprains b) Cervical Spondylosis c) Pulled Muscles d) Post Fracture Pain e) Fibrositis of the Neck f) Acute Lumbago g) Chronic Back Aches h) Tortic...
941/44, PARINAMAM LINE, OPP : WATER AUTHORITY OFFICE, KALOOR Kochi, KERALA - India
View Contact Number Get a QuoteElectro Neurostere produces electrical impulses that relieves pain. It also accelerates the reunion of fracture. The electrical impulses work to stimulate bone growth, in that it appears to trigger certain chemical process that normally take place during bone development. This instrument is tested at many centres in India and found to be eminently useful in relieving pain. RELIEVES a) Acute Sprains b) Cervical Spondylosis c) Pulled Muscles d) Post Fracture Pain e) Fibrositis of the Neck f) Acute Lumbago g) Chronic Back Aches h) Torticollis i) Trigiminal Neuralgia j) Spasms k) Head Aches Pain is often produced due to (1) incordination of muscle fibres (2) accumulation of toxins like lactic acid in the tissues and (3) when blood flow to a certain area is reduced. The muscle is contracted when one electrical impulse is given and relaxed during the interval between two impulses. Thus the muscle is completely stimulated so as to re-arrage the muscle fibres in their proper order. By passing electrical impulses we are passing electric charges which in turn ionize the toxins like lactic acid and remove them. When one electrical impulse is being passed there is contraction of the tissues in that area. Then in the interval between two impulses there is relaxation and a region of reduced pressure is produced in these tissues. Thus the blood from the adjacent tissues will flow into them. This process is repeated and the blood flow in that area is accelerated reducing the pain. We have three model of this instrument. 1. 16823. TE .............MINOR(for the patient) 2. 16821. TE .............COMPACT (clinical model) 3. 16822. TE .............PROFESSIONAL (hospital model) (i)16823. TE Is the simplest of the three models and a patient can safely use this by himself. It works on two dry cells (Input 3V. D.C.). At the output pulses from 1 in 2 sec. To 50 per sec is produced. There is a control marked "PULSE" to vary the pulse rate. A control marked "INTENSITY" regards the intensity as required by the patient. An L.E.D. indicator flickering at the same rate as electrical impulses helps to determine the rate of impulses given out. (ii)16821. TE This is the clinical model and is similar to 16823. TE. It works on three dry cells (4.5 V.D.C.) the intensity and the pulse rate can be separately controlled in this instrument. The intensity can control in this Instrument. The intensity can be controlled in this to a greater range to the required high value. There ate two indicators in this: a flickering L.E.D. flickering at the same rate as the rate of impulse and an audio producing a beeping sound corresponding to the rate of electrical impulses. (iii)16822. TE this is professional model meant for hospitals. To this addition to the above controls, there is a control for the diration of each electric pulse. Smooth electrical pulses the rate, intensity and duration of which can be controlled to a great range. This works on special 1. Cs and makes it professional. There are audio and visual indicators in this In addition to the above there is a device in this known as the sensor for the sensitivity test. This is to locate the spots of maximum intensity of pain. It is based on the fact that the skin resistance varies considerably with pain. (i) MICRO PULSE GENERATOR : MODEL - 16817 TE This is a monopolar wave generator which is used for needle to plate stimulation. In this case needle electrode alone is effective for stimulation. Here the needle electrode alone is effective for stimulation. Here the needle is connected to the negative terminal of the stimulator output and the plate of a cylindrical rod is connected to the positive terminal. This produce electrical pulses or current in a few micro ampere which build up negative ions at the focus pain. This causes relief and cure of pain. The current varies from 100 micro 25 ampere to 2 milli ampere and voltage from 5 V to 40 Volts. This equipment is also provided with a scanner. The scanner is similar to the point detector in the acupuncture. Here the painful points can be sensed using the scanner by the property to their low electrical resistance. When the point is touched the instrument produces a shrill sound and the Galvanometer provide in the machine shows maximum deflection indication the low skin resistance. (ii)GALVANIC / FARADIC STIMULATOR: MODEL - 16819 TE It has been found that muscles which are in a state of fatigue become considerably strengthened after treatment with a galvanic current. Hence a galvanic stimulator is highly useful on physiotherapy. The application of faradic current causes contraction and relaxation of muscle and it is recommended for paralyzed muscles or muscles damaged by diseases. Here is also provision in this instrument for surging the faradic and galvanic wave forms. There are various causes for paralysis - the nerve cells lose their functions and cannot generate impulses, or the transmission channel is broken and stops sending the impulses. To the muscles themselves have some trouble moving and so on. In this former two cases, since the muscles, themselves are capable movement, we can send low frequency electric waves into the body, which mechanism is similar to that of the impulse racing through the nerves getting them excited enough to generate the impulses needed to move the muscles. This is the treatment method for paralysis using a low frequency electro-stimulator for rehabilitation on hospitals or at home. It is said that this treatment is performed by applying the electro-physiology of the nerves and muscles directly.
Established in the year 1981 at Kochi, Kerala, Mohans Electronics & Illuminators are reputed for manufacturing, supplying and trading to our clients a wide range of Hospital and Medical Equipment. Our products range from Transcranial Magnetic Stimulator, EMG Biofeedback Equipment, ECT Equipment, Electroconvulsive Therapy Equipment, Behavior Therapy Unit, Alpha Wave Generator, Shortwave Diathermy Unit, Electric Heating Pads, Slim Up Beauty Pulse, Asthma Guard etc. and many more of such related products. Our products are in much demand and can with stand competition because they possess essential characters like durability, easy to use features, affordability and resistance to corrosion.We give prime importance to quality and so make sure that all our products deliver what we promise to our clients. With the help of latest infrastructure and machinery coupled with leading technology, our efficient team puts in every effort to manufacture products that are technologically advanced and beneficial for our clients. Our efforts have earned us recognition in the international market as well. Since the functionality of every product is critical and makes an impact on the health of people, we take special care to use excellent spare parts and ensure that our machines are accurate. All the products offered by us are of good quality with excellent finishing. Our work force undergoes rigorous training to stay updated with the latest technological advancements and ensure our products are never outdated. Clients can avail uniform supply in the market and have any product that will serve their purpose. Another contributing factor is our mentor, Mr. V. Mohan Das, whose exceptional leadership and guidance has been a major contributing factor in our company’s achievements. With years of experience and a pleasing personality, he has nurtured every talent and raised our professionals to excel and deliver quality work. Our organization is determined to stay ahead of competition and garner the appreciation of our clients.
Wholesale Supplier
1981
11-50
Proprietorship
V. Mohan
941/44, PARINAMAM LINE, OPP : WATER AUTHORITY OFFICE, KALOOR, Kochi, KERALA - India
copyrights © 2024 naturaltherapyindia.com. All rights reserved.